Consultancy Servies for Design and Development of Benchmarking Energy Indicator System for Lift Installations
(REF: P-0170) |
Matched I&T Wish |
Benchmarking Energy Performance Indicator for Lifts (REF: W-0234) |
Matched I&T Solution |
Benchmarking Energy Performance Indicator System for Lifts (REF: S-0276) |
Solution Feature |
- To justify the use of the most appropriate energy performance benchmarking parameter, <J/kg-m>, for a lift irrespective of type, brand and model by simulation.
- To develop a prototype to measure the parameter with a long-termed goal to arrive at a threshold value for the Building Energy Code.
- To develop added-on devices to facilitate the measurement, including energy, distance traveled and car load, without downgrading the safety standard of the lift.
- To develop the wireless inteface between such devices and an in-machine-room computer.
- To compile the software on the computer to display the parameter continuously and statistically and study the feasibility of additional functions such as brake monitoring.
|
Trial Information |
Trial Site |
: |
EMSD Headquarters |
Trial Scale |
: |
1 no. of system |
Trial Duration |
: |
Apr 2020 to Dec 2020 |
|
Final Report |
EMSD-M&V-P0170-W0234-S0276_Final.pdf
|
Info on I&T Solution Provider |
Solution Provider | : | Bomy Development Limited | Address | : | Room 1907, 19/F, Eastern Commercial Centre, 397, Hennessy Road, Wan Chai, Hong Kong | Contact Person | : | Ms Corina K. L. Chan |
Position | : | Administrative Manager | Tel | : | 852-9303-2169 | Email | : |
corina.chan.is@gmail.com |
|