| Trial Project |
Guided Wave Inspection Device for Lamp Pole Corrosion
(REF: P-0316) |
| Matched I&T Wish |
|
| Matched I&T Solution |
|
| Solution Feature |
- The Guided-Wave-based (GW) system is an innovative technology that has been well-proven to be effective in determining the extent of defects and corrosion occur in partially buried pipes and ducts.
- The GW system consists of a laptop PC, a small USB-based data acquisition box and our innovatively designed smart sensors. It is portable and can be powered up via a USB plug or a battery pack.
- As of today, there is no commercial system can compete with our GW system based on the cost, ease-of-use and flexibility.
- The design of smart sensor is patented in US. It is thin and flexible with a smart material patch and our designed harmonized flexible printed coil (HFPC). It can be mounted on different sizes and shapes of poles. As of today, no commercial system can provide such compatibility.
- Not like other systems that their data cannot be extracted by users, the data collected by this system are opened to users for further analysis. In future, the collected maintenance data can be transferred to remote maintenance centre via Wi-Fi and performed AI-based proactive maintenance.
|
| Trial Information |
| Trial Site |
: |
Causeway Bay Sports Ground |
| Trial Scale |
: |
5 no. of poles for corrosion detection |
| Trial Duration |
: |
Oct 2024 to Oct 2025 |
|
| Additional Solution Information |
Additional Info - English-Chinese Aggregating Pneumatic Tightening Mechanism to Smart Sensor.pdf
|
| Info on I&T Solution Provider |
| Solution Provider | : | Ir Dr. Peter W. T. TSE and Ir Dr. Eric S. W. WONG | | Address | : | Room N105, 11/F, Valiant Industrial Centre, 2-12 Au Pui Wan Street, Fo Tan, Shatin, Hong Kong SAR, China | | Contact Person | : | Ir Dr. Peter W. T. TSE |
| Position | : | Consultant and Professor | | Tel | : | +852 92660207 or +1 672 8332208 | | Email | : |
peterptpt@yahoo.com.hk | | Webpage | : | https://www.seam-cndt.com |
|