Skip to main content

section banner

Project Matching

Field Test Trial of Lift Suspension Rope Inspection Device

Trial Project Field Test Trial of Lift Suspension Rope Inspection Device
(REF: P-0182)
Matched I&T Wish Elevator Suspension Rope Inspection Device Using Magnetic Flux Leakage (MFL) Technology
(REF: W-0306)
Matched I&T Solution Elevator Suspension Rope Inspection Device [Hardware/Service]
(REF: S-0792)
Solution Feature
  • Magnetic rope inspection using Magnetic Flux Leakage (MFL) and Giant Magnetoresistance (GMR) technologies
  • 24x7 remote real-time monitoring of lift rope
  • Comprehensive elevator rope non-destructive testing (NDT)
  • Integrated web portal
  • Available in both portable device and permanent installation
Trial Information
Trial Site : EMSD Headquarters Lift No. 9
Trial Scale : 1 no. of Lift
Trial Duration : May 2021 to May 2022
Final Report EMSD-M&V-P0182-W0306-S0792_Final.pdf
Info on I&T Solution Provider
Solution Provider:RaSpect Intelligence Inspection Limited
Address:Flat/RM 308, 3/F, InnoCentre, 72 Tat Chee Avenue, Kowloon Tong
Contact Person:Tony Ip
Position:Assistant Project Manager
Tel:95579125
Email: tony.ip@raspect.ai
Webpage: https://raspect.ai/en/